24GHz Small-space presence sensor(ON/OFF version)
MSA215 99 is a 24GHz radar sensor based on Merrytek patented multi-array antenna. Its antenna has high gain and very narrow detection range.Combined with Merrytek’s unique software algorithm,it can accurately detect minor movements brought by human in almost all indoor spaces and best presence detection solution for workspace and toilet cubicle etc small-space scenes.
| Input/Output | Input voltage | 100-240V AC 50-60Hz |
| Rated voltage | 220V AC | |
| Working current | 50mA max | |
| Power consumption | ≤1W 230V AC | |
| Load capacity | 800w resistive loading or 400w inductive loading | |
| Loading instant peak current | 30A | |
| Sensor parameter |
Radar frequency | 24.125GHz±125MHz ISM band |
| Radar transmit power | 5mW Max | |
| Detection Area | DIP or remote setting: 25%-100% | |
| Hold Time | DIP or remote setting: 5s-30min | |
| Radius detection range(based on 100% sensitivity) |
Motion detection(3m height): 0.5-1.5m Minor motion detection(3m height): 0.5-1.5m Presence(3mheight): 0.5-1.5m |
|
| Daylight sensor | 5-150lux/Disable | |
| Remote control | Available | |
| Mounting height | 2-4.0m | |
| 3dB beam angle | 30°(horizontal) | |
| 30°(vertical) | ||
| Application environment | Drill hole | Ф65-70mm |
| Installation | Flush mounting | |
| Working Temperature | 0℃…+50℃ | |
| Storage Temperature | ‘-25℃~+80℃ | |
| Certificate Standard | Certificate | CE/FCC/RED |
| Environmental Requirement | Compliant to RoHS | |
| IP Rating | IP20 | |
| “N/A” means not available | ||
Product dimension
Initialization
When powered on,sensor indicator will turn off after flashing for 20S and will not detect moving signal during this time. After 20S,you can use our MH10 remote or dip switch to adjust detection area、hold time and daylight sensor etc parameter.
Factory setting
Detection Area:100%, Hold Time: 1Min, Indicator light: Open, Daylight sensor: Disable
Detection Signal
The product detects human moving, minor moving, and presence signals, and realizes the detection of human-existing/no-human in non-sleep state. The following is a description of the moving, minor moving and presence signals:

Wiring layout suggestion:
1. LN terminal stands for AC input, L’N’ stands for AC output,please wiring correctly
2. One sensor’s max loading capacity is 800w resistive loading and 400w inductive loading for one single load.if you want connect more load in one loop,we recommend to add an AC contactor in our output LN terminalto avoid momentary surge overload.