                | Charge Part | KE002 | 01M / 01A180KB1 | 02M / 02A180KB | 03M / 03A180KB3 | 
| Rated input voltage | 220-240Vac 50Hz/60Hz | |||
| Rated input current | 0.06A Max. @230Vac | |||
| Input inrush current | 30A(twidth=100uS 50% Ipeak )@230Vac(Cold start at full load ) | |||
| Power factor | ≥0.5@230Vac | |||
| Input power | <4W | |||
| Battery charging current (Max) | 240mA | |||
| Battery charging time | 24 hours Max. | |||
| Emergency Part | Operating mode | Emergency mode | ||
| Load type | LED | |||
| Emergency power | 1W | 2W | 3W | |
| Emergency time | 3hours | |||
| Load output current | 50-15mA | 100-30mA | 150-50mA | |
| Load output voltage | 20-60VDC | |||
| Battery | Li-ion (The battery capacity meets the emergency time at 25℃) | 3.7V 2000mAh | 3.7V 2600mAh | |
| Battery warranty | Warranty 3 year, @25℃. | |||
| Exception Driver Requirements | Surge current | 8A | ||
| Input current | 3A Max. | |||
| Output current | 2A | |||
| LED Indication | Charging | Green light | ||
| Fault | Green light off | |||
| Emergency Function Test | Manual test | Yes | ||
| Auto test | KE002-01A180KB1 / KE002-02A180KB / KE002-03A180KB3 | |||
| Auto Testing | Fault / test / Status | Reason | Charge Indicator Status | |
| Battery fully charged and operational | Standard daily use | solid green | ||
| Battery Charging | Initial Charge/Battery Top Up | Flashing green 1 sec on 1 sec off | ||
| Auto Test 3 Hours (every 12 months) | Periodic self test | Flashing Green 3 sec on 1 sec off | ||
| Auto Test 5 min (every 30 days) | Periodic self test | Flashing Green 3 sec on 3 sec off | ||
| Duration test fault | Failed the 3 hour annual test | Flashing Red 0.5 sec on 0.5 sec off | ||
| LED fault | Not plugged in or damaged/faulty | Flashing Red 2 sec on – 2 sec off | ||
| Battery Disconnected/Faulty | Not plugged in or damaged/faulty | solid red | ||
| Emergency protection | Battery over-charge/deep discharge protection | Yes | ||
| Output over-voltage protection | Yes | |||
| Output overload protection | Yes | |||
| Output short circuit protection | Yes | |||
| Operating Environment | Operating temperature/humidity | 0℃…+50℃humidity:20%-75%(without condensation) | ||
| Storage temperature/humidity | -5℃-35℃ | |||
| Case Max. Temp(Tc) | 75℃ | |||
| Safety & EMC | Withstand voltage | 3000Vac 5mA 60s (Input “L N” – output “SEC+ SEC-) | ||
| Safety standard | EN61347-1, EN61347-2-7 | |||
| EMC standard | EN55015, EN61000-3-2, EN61000-3-3 | |||
| Battery standard | UN38.3 | |||
| Environmental protection requirements | Compliant to RoHS | |||
| Certification | CE | |||
| Others | Input/output(terminal/wiring) specification | Press terminal, wire diameter:0.5-0.75mm2 | ||
| IP rating | IP20 | |||
| Type of protection | Class 2 | |||
| Installation type | Built-in installation | |||
| Installation dimension | 137*42*22mm | |||
| Packaging requirement | White box+Instruction manual+clapboard+outer carton(K=A) | |||
| Weight :Emergency Power Supply | 110g | |||
| Lifespan | 5 Year @Ta ( Battery not included ) | |||
| Notes:All parameters are tested on the input voltage 230Vac,environment temperature 25℃,unless otherwise specified. | ||||