  • Constant power output LED emergency power supply with a wide output voltage range;
  • Inputrelay switching.
  • With multiple protection functions: battery overcharge, over discharge protection, output short circuit protection.protection.

Dimension & Function Diagram

Parameter characteristics

Charge Part KE002 01M / 01A180KB1 02M / 02A180KB 03M / 03A180KB3
Rated input voltage 220-240Vac 50Hz/60Hz
Rated input current 0.06A Max. @230Vac
Input inrush current 30A(twidth=100uS 50% Ipeak )@230Vac(Cold start at full load )
Power factor ≥0.5@230Vac
Input power <4W
Battery charging current (Max) 240mA
Battery charging time 24 hours Max.
Emergency Part Operating mode Emergency mode
Load type LED
Emergency power 1W 2W 3W
Emergency time 3hours
Load output current 50-15mA 100-30mA 150-50mA
Load output voltage 20-60VDC
Battery Li-ion (The battery capacity meets the emergency time at 25℃) 3.7V 2000mAh 3.7V 2600mAh
Battery warranty Warranty 3 year, @25℃.
Exception Driver Requirements Surge current 8A
Input current 3A Max.
Output current 2A
LED Indication Charging Green light
Fault Green light off
Emergency Function Test Manual test Yes
Auto test KE002-01A180KB1 / KE002-02A180KB / KE002-03A180KB3
Auto Testing Fault / test / Status Reason Charge Indicator Status
Battery fully charged and operational Standard daily use solid green
Battery Charging Initial Charge/Battery Top Up Flashing green 1 sec on 1 sec off
Auto Test 3 Hours (every 12 months) Periodic self test Flashing Green 3 sec on 1 sec off
Auto Test 5 min (every 30 days) Periodic self test Flashing Green 3 sec on 3 sec off
Duration test fault Failed the 3 hour annual test Flashing Red 0.5 sec on 0.5 sec off
LED fault Not plugged in or damaged/faulty Flashing Red 2 sec on – 2 sec off
Battery Disconnected/Faulty Not plugged in or damaged/faulty solid red
Emergency  protection Battery over-charge/deep discharge protection Yes
Output over-voltage protection Yes
Output overload protection Yes
Output short circuit protection Yes
Operating Environment Operating temperature/humidity 0℃…+50℃humidity:20%-75%(without condensation)
Storage temperature/humidity -5℃-35℃
Case Max. Temp(Tc) 75℃
Safety & EMC Withstand voltage 3000Vac 5mA 60s (Input “L N” – output “SEC+ SEC-)
Safety standard EN61347-1, EN61347-2-7
EMC standard EN55015, EN61000-3-2, EN61000-3-3
Battery standard UN38.3
Environmental protection requirements Compliant to RoHS
Certification CE
Others Input/output(terminal/wiring) specification Press terminal, wire diameter:0.5-0.75mm2
IP rating IP20
Type of protection Class 2
Installation type Built-in installation
Installation dimension 137*42*22mm
Packaging requirement White box+Instruction manual+clapboard+outer carton(K=A)
Weight :Emergency Power Supply 110g
Lifespan 5 Year @Ta ( Battery not included )
Notes:All parameters are tested on the input voltage 230Vac,environment temperature 25℃,unless otherwise specified.

Product details

Manual Test & Operation Instructions

  1. Connect the wire according to wiring diagram.
  2. L,N power on, Switch on S1. then the load lamp turns on, The emergency driver indicator light will turns green, emergency power supply normal charging. Turn off Switch S1, the load lamp turns off.
  3. Emergency Simulation: Switch on, the load lamp turns on, press the switch(TEST SWITCH), then switch to emergency mode, the indicator light of emergency driver will be extinguished. Release the switch(TEST SWITCH),  then lamp is powered by led driver, the indicator light will turn on.

 

Automatic Test& Operation Instructions

  1. Connect the wire according to wiring diagram.
  2. AC power is off, and the clock lasts for 15 days, Power on and re-time.
  3. To replace the battery, turn off the power supply, Re-time.

 

Battery Application Notice

  1. The battery should be recharged and discharged semiannually in normal use conditions.
  2. Do not connect to the circuit when the battery is not use to prevent over-discharge of the battery due to self-consumption of the circuit board.
  3. Please keep the battery from the heat source when installing and using, and only be allowed to use in certain working temperature range.
  4. The battery should be stored in a cool and dry environment.
  5. After long time storage, the battery is cycled every 12 months as required.

Wiring suggestions

Installation suggestion

N/A

Related Products