Input | Operating Voltage | 198-264VAC 50Hz /60Hz | ||||||
Rated Input Voltage | 220-240VAC 50Hz /60Hz | |||||||
DC Input Voltage range | 176-280VDC | |||||||
Input Current | 0.6A Max. | |||||||
Input Inrush Current | <25A (Half current pulse width 100US) @230VAC | |||||||
Power Factor | ≥0.95 @230VAC (Full load) | |||||||
Total harmonic distortion | Typical: 15% (@230Vac, 100% load) | |||||||
Stand-by Power | ≤0.5W(@230Vac when PUSH or DALI turn off) | |||||||
Efficiency | 93%Max. @230VAC (Full load) | |||||||
Wiring Method | Push terminal, wire cross section:0.5-1.5mm² | |||||||
Automatic circuit breaker (Calculate current in the wire) |
type | B10 | B13 | B16 | B20 | B25 | / | |
Number | 10 | 12 | 15 | 18 | 20 | / | ||
type | C10 | C13 | C16 | C20 | C25 | C32 | ||
Number | 12 | 16 | 20 | 25 | 30 | 40 | ||
Output | Operating mode | Constant Current | ||||||
Load type | LED | |||||||
Ripple requirement (Flickering or flickering-Free) | Flicker value: less than 2% for whole dimming range | |||||||
Start up time | <1s (@230Vac) | |||||||
No-load output voltage | 430VDC Max. | |||||||
Load output voltage range | 80-300VDC | |||||||
Full load output power | 120W Max. | |||||||
Load output current | 300MA(80-330V) 350MA(80-330V) 450MA(80-266V) 500MA(80-240V) 550MA(80-219V) 650mA(80-185V) 700mA(80-172V) |
|||||||
Constant current/voltage Precision | Constant Current Precision ±5% | |||||||
Wiring method | Push terminal, wire cross section:0.5-1.5mm² | |||||||
Control Method | Primary PUSH Dimming | Primary PUSH dimming (Max.lead length:20M) | ||||||
Dimming Range | Primary PUSH & DALI dimming: 0%-100% | |||||||
DALI Dimming | DALI dimming (Max.lead length:300M) | |||||||
Exception Protection Requirements | Output over temperature protection | Yes, without self recovery function(Can be inquired) | ||||||
Output short circuit protection | Yes, without self recovery function(Can be inquired) | |||||||
Operating Environment | Operating temperature/ humidity | -25℃~50℃ Humidity:85% (Non-condensing) | ||||||
Storage temperature/ humidity | -40℃~80℃, Humidity:10%–95% | |||||||
Max. case temp(Tc) | 85℃ | |||||||
Safety & EMC | EMC standard | EN55015 EN61547 EN61000-3-2 EN61000-3-3 | ||||||
DALI protocol standard | IEC62386-102 IEC62386-207 DT6 | |||||||
Safety standard | EN61347-1 EN61347-2-13 | |||||||
Certification | CE | |||||||
Mains surge capability | 1kV (@“L – N”) ; 2kV (@“L/N – PE”) | |||||||
Others | Degrees of protection | IP20 | ||||||
Type of protection | Class I | |||||||
Installation type | Independent installation | |||||||
Installation dimension | 284×30*20mm | |||||||
Blackout memory function | Yes, PUSH blackout memory | |||||||
PUSH dimming synchronization | 15 units Max. | |||||||
Packaging requirement | white box+ Instructions Clapboard Outer Carton(K=A) | |||||||
Weight | 260g | |||||||
Life | 5 years guarantee @Ta full load | |||||||
Note: All parameters are tested at the input voltage of 230Vac and 25 degree environment unless specified. |
ON/OFF & Description of Dimming Operation
N/A