HomeProducts

MC116D RC

Networking controller

Get a Quote

Features

  • Grouping networking by 2.4G wireless, no need paring or gateway.
  • Patented di-pole microwave antenna, no false trigger when installed beLOW metal LED tray.
  • Super-narrow microwave senor head, suitable to be fixed in slim LED fixtures.
  • All sensor parameters can be set by remote control.
  • Output 0-10V dimor PWM dim, 2-step/3-step dim function.
  • 6m Max. mouthing height.

Size and Function Diagram

Parameter characteristics

Input Rated voltage 12±1VDC
Working current 55±5mA
Ripple voltage < 100mVp-p
Output Output signal ○0-10V Dimming Signal ○PWM Dimming Signal
Sensing parameters Working frequency 5.8GHz ±75MHz, ISM band
Transmit power 1mW Max.
Daylight priority ON 15Lux (LOW) 50Lux (MED) Disable (HIGH)
OFF 100Lux 150Lux
Stand-by DIM Level < 50mA(Non-constant source)
10%(1.4-1.6V)    30%(2.9-3.3V)
Detection range (radius) Ceiling Mounting(height: 3m): 0.3m/s ≥4m, 1m/s ≥2.5m
Wall Mounting(height: 2m): 0.3m/s ≥8m, 1m/s ≥4m
Installation height 3m ( 6m Max )
3db beam angle 80 °@XZ plane
96 °@YZ plane
Wireless Module Operating Frequency 2.4GHz
Transmitting Power 6dBm
Transmitting Distance 15m MAX(Point-to-point open area transmission distance)
Environment Working temperature Built-in: -25~60℃
Storage temperature -40℃~80℃, humidity ≤85% (non-condensing)
Certification Standards Certified CE
Environmental requirements Comply with RoHS 2.0 , Reach requirements
Degree of protection IP20
Other Wiring 3pin 2.0mm terminal
Installation requirements built-in installation
Packaging requirements Clapboard + paper carton(K=A)
Net weight 16.5±3g
Life 5 Years Warranty@Ta

Product details

Initialization

When powering on for the first time, the sensor will turn the light on to 100% brightness, and the light will be turned off after 10 seconds. During initialization, movement signal will not be detected.

 

Default setting

Detection area: 100%; Hold Time: 10s; Stand-by Period: 0s; Daylight Sensor: Disable;

Stand-by Dim Level: 10%.

 

Application Notice

  • The sensor should be installed by a professional electrician. Please cut off the power before installing, wiring etc.
  • The detectiondistance is related to factors such as the moving speed of the moving object, the size of the moving object, the installation height, the installation angle, whether the installation environment is open, and the material of the reflector. The detection distance given in the specification is a typical value, which is 165cm/65kg tester, and it is tested in an open indoor environment
  • When the microwave sensor is installed on the wall, the detection distance will be greatly increased compared with that installed on the ceiling. If you use the wall installation method, please reduce the sensitivity to use or contact our company to confirm the use settings. The light sensitivity threshold is in a sunny environment, no shadows, and ambient light diffuse reflection conditions. In different time periods, climates, and environments, the illuminance value detected by the light sensor may be different
  • Sensor parameters may need to be reconfigured in different installation environments, please refer to the following instructions or contact the manufacturer
  • This sensor is only for indoor use, outdoor wind and rain, and surrounding moving objects will cause false triggering
  • The installation height of the sensor product cannot exceed 6 meters, and the optimal height is 3 meters; the distance between the two sensors should be greater than 3 meters
  • When the sensor is installed in a metal lamp, on a metal reflective surface, or in a narrow closed environment, microwaves will be reflected multiple times and cause false triggering. Please reduce the sensor sensitivity or contact the manufacturer for technical support.
  • Please make sure that there are no moving signals such as fans, DC motors, sewer pipes, air outlets, etc. around the sensor, otherwise the sensor may cause false triggering.
  • Microwaves cannot penetrate metal, avoid installing in closed or semi-closed metal lamps, and there should be no metal or glass blocking the product
  • Sensor with different0-10V / PWM driver, LOW light effect may be different
  • DC regulated power supply with stable output voltage and LOW ripple coefficient must be used. The ripple of the power supply should be less than 100mV ; the load current should be greater than 100 mA
  • Product specifications and parameters may be optimized without prior notice
  • For the new installation environment, it is recommended to test 5pcs samples before

Wiring suggestions

Installation suggestion

N/A