Models | MLC16C-DP2 | MLC25C-DP2 | |||
Input | Voltage rage | 198-264Vac 50Hz /60Hz | |||
Rated voltage | 220-240V AC 50Hz/60Hz≤0.12A(@230Vac full load) | ||||
Input current | ≤0.095A(@230Vac full load) | ≤0.12A(@230Vac full load) | |||
Inrush current | <15A (100us half-current)@230V AC | ||||
Power factor | ≥0.90 (230V Max load) | ||||
Stand-by power | <0.5W@230VAC | ||||
Working efficiency | ≥85% (230V Max load) | ≥83% (230V Max load) | |||
Lightning surge | LN: 1KV | ≥83% (230V Max load) | |||
Output | Working model | CC | |||
Type of load | LED | ||||
Full load power | 16W Max | 23.1W Max | |||
Flicker ripple | ≤5% | ||||
No-load output voltage | 60VDC Max | 50VDC Max | |||
Load current | Single current : 200mA / 280mA / 300mA 320mA / 350mA |
Single current : 450mA / 500mA / 550mA 600mA / 700mA |
|||
Load output voltage range | 36- 52Vdc:200mA/280mA/300mA 36-50Vdc:320mA 36-46Vdc:350mA |
24- 42Vdc:450mA/500mA/550mA 24- 36Vdc:600mA 24-30Vdc:700mA |
|||
Constant current accuracy | ±5% @230VAC | ||||
Parameters | Operating frequency | 5.8GHz ±75MHz,ISM band | |||
Transmitting power | 1mW max | ||||
Detection Area | 25%/50%/75%/100% | ||||
Hold Time | 5S/90S/3min/10min | ||||
Stand-by Period | 0S/30S/10min/+∞ | ||||
Daylight control | Daylight threshold | 5Lux/15Lux/50Lux/Disable | |||
Daylight priority open/close | Open:5Lux / 15Lux / 50Lux close:50Lux / 100Lux / 150Lux |
||||
Stand-by DIM Level | 0.2 | ||||
Detecting radius(sensitivity: 100%) | Ceiling mounting 3m:0.3m/S ≥3m,1m/S ≥2m | ||||
Mounting Height | 3m Typical Value (6m Max ) | ||||
3db field angle | 90°@Xz flat 95°@Yz flat |
||||
Abnormality Protection Requirements | Input over voltage protection | Yes, self-recovery | |||
Input no-load protection | Yes, self-recovery | ||||
Short-circuit protection | Yes, self-recovery | ||||
Withstand voltage | 3750V AC 5mA 60S (input “L N” to output SEC+ SEC-) | ||||
Operating temperature | -25~+45℃ | ||||
Maximum temperature(Tc) | 85℃ | ||||
Storage temperature/humidity | -40℃~+80℃ Humidity:85% | ||||
Certificate Standards | Safety standards(LVD) | EN61347-1,EN61347-2-13 | |||
EMC standards | EN55015,EN61547,EN61000-3-2,EN61000-3-3 | ||||
Environmental requirement | Compliant to RoHS | ||||
Certificate | CE RED | ||||
Protection class | Class II | ||||
IP Rating | IP20 | ||||
Others | Wiring method | Press terminal, wire diameter:0.5-1.5mm² | |||
Installation | Built-in | ||||
Installation size | Φ: 68mm,H: 28.5mm | Φ82mm,H27.25mm | |||
Package | PE bag clapboard, carton(K=A) | ||||
Lifetime | 3 years warranty@Ta 230V full load | ||||
Note:The given values of detecting parameter is typical measured by 165cm high testers in an indoor open environment. |
Initialization
When power on, the product automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the product is not able to detect moving signals.
Factory Setting
Sensitivity: 100%; Hold Time: 5S; Stand-by period: 0S; Daylight Sensor: Disable.
Application Notice
Note: The product can be connected to only one load. Connecting more than one load will damage product.
N/A