                | Input | Rated voltage | 12±1VDC | |||
| Working current | 55±5mA | ||||
| Ripple voltage | < 100mVp-p | ||||
| Output | Output signal | ○0-10V Dimming Signal | ○PWM Dimming Signal | ||
| Sensing parameters | Working frequency | 5.8GHz ±75MHz, ISM band | |||
| Transmit power | 1mW Max. | ||||
| Daylight priority | ON | 15Lux (LOW) | 50Lux (MED) | Disable (HIGH) | |
| OFF | 100Lux | 150Lux | |||
| Stand-by DIM Level | < 50mA(Non-constant source) 10%(1.4-1.6V) 30%(2.9-3.3V) | ||||
| Detection range (radius) | Ceiling Mounting(height: 3m): 0.3m/s ≥4m, 1m/s ≥2.5m Wall Mounting(height: 2m): 0.3m/s ≥8m, 1m/s ≥4m | ||||
| Installation height | 3m ( 6m Max ) | ||||
| 3db beam angle | 80 °@XZ plane | ||||
| 96 °@YZ plane | |||||
| Wireless Module | Operating Frequency | 2.4GHz | |||
| Transmitting Power | 6dBm | ||||
| Transmitting Distance | 15m MAX(Point-to-point open area transmission distance) | ||||
| Environment | Working temperature | Built-in: -25~60℃ | |||
| Storage temperature | -40℃~80℃, humidity ≤85% (non-condensing) | ||||
| Certification Standards | Certified | CE | |||
| Environmental requirements | Comply with RoHS 2.0 , Reach requirements | ||||
| Degree of protection | IP20 | ||||
| Other | Wiring | 3pin 2.0mm terminal | |||
| Installation requirements | built-in installation | ||||
| Packaging requirements | Clapboard + paper carton(K=A) | ||||
| Net weight | 16.5±3g | ||||
| Life | 5 Years Warranty@Ta | ||||
Initialization
When powering on for the first time, the sensor will turn the light on to 100% brightness, and the light will be turned off after 10 seconds. During initialization, movement signal will not be detected.
Default setting
Detection area: 100%; Hold Time: 10s; Stand-by Period: 0s; Daylight Sensor: Disable;
Stand-by Dim Level: 10%.
Application Notice

N/A
 
                    