Input | Rated Voltage | 120/277V AC 50/60Hz |
Stand-by Power | ≤0.5W | |
Surge Test | 1KV(L/N,EN61000-4-5) | |
Output | DC Output | 12VDC 100mA(Max) |
Load Type | 400W@230Vac(Inductive Load), 800W @230Vac(Resistive Load) | |
Load Surge Current | 30A(@ 50% Ipeak, twidth 500us @230Vac full load & start at cold load.) 60A(@ 50% Ipeak, twidth 200us @230Vac full load & start at cold load.) | |
Interface | Dimming Interface | 3.5mm Earphone interface / Tpye-C port |
Environment | Operating Temperature | -25~60℃ |
Storage Temperature | -40℃…80℃, humidity≤85%(Non-condensing) | |
Certificate Standards | Certificate | UL CE |
Environmental Requirement | Compliant to RoHS 2.0, Reach | |
Safety (LVD) standard | EN61058-1-2, EN61058-1 | |
EMC Standards | EN61058-1,EN61000-3-2,EN61000-3-3,EN62479, EN301489-1, EN55015, EN300440 | |
IP Rating | IP65(match waterproof lamp) | |
Product classification | Class II | |
Others | Wiring | Lead wire Input: 18AWG(N: White L: Black) Output: 24AWG(+: Purple -: Pink) Lead wire with 300mm long |
Installation | Side mounting / Built-in installation | |
Package | Bubble bag + cardboard + outer carton(K=A) | |
Net Weight | 90±3g | |
Lifetime | 5 years warranty@Ta 230Vac full load |
Product Options:
Earphone interface, Built-in installation
*This product is designed to only connect to one AC load.
Connecting more than one load may cause damage.
Application Notice
Sensor should be installed by a professional electrician.
Please turn off power before installation.