                | Input | Rated Voltage | 110-240VAC 50/60Hz | 
| Stand-by Power | ≤0.2W | |
| Surge Test | L–N: 1kV | |
| Output | Output Control | ON-OFF | 
| Load Capacity | 200W(Inductive/LED) ; 400W(Resistive) | |
| Max. Surge Capacity | 30A (50% Ipeak, twidth =200us, 230Vac full load, cold start) | |
| Sensor Parameter | Operating Frequency | 5.8 GHz ±75MHz, ISM wave band. | 
| Transmitting power | 1mW Max. | |
| Detecting Radius | Ceiling installation 3m height: 1m/s ≥ 2.5m, 0.3m/s ≥ 3.5m Test condition: Product setting 100% sensitivity, 60 ㎡ indoor open space | |
| Mounting Height | 3m (5m Max ) | |
| Environment | Operating Temperature | -25~60°C | 
| Storage Temperature | -40℃~80℃, Humidity: ≤85%(Non-condensing) | |
| Maximum Shell Temperature (Tc) | 80℃ | |
| Certificate Standard | Certificate | CE, RED, TUV | 
| Environmental Requireme nt | Compliant to RoHS 2.0, Reach | |
| IP Rating | IP20 | |
| Product Category | Class 〡 | |
| Other | Wiring | Press-in type terminal block, wiring 0.5-0.75 mm² | 
| Installation | Built-in | |
| Package | Bubble bag + Clapboard + Carton(K=A) | |
| Net Weight | 25.2±3g | |
| Lifetime | 5 years warranty @Ta | 
Initialization
After power on, the sensor automatically turns on light to 100% brightness and turns off light after 10 seconds. During initialization, sensor is not able to detect movement.
Default setting
Sensitivity: 100%, Hold time: 5s, Daylight sensor: Disable
Application Notice

Note:
*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.

Note:
When installation, please pay attention to the front of microwave antenna is not allowed to be blocked by metal.
The AC incoming line needs to keep a distance of more than 10mm from the BUCK inductance, Otherwise it will cause conduction to fail. As shown in the following figure.
 
                    