Input | Input Voltage Range | 7.5-12VDC |
Rated Input Voltage | 12V DC | |
Operating Current | <25mA | |
Voltage Ripple | <100mVp-p | |
Output | Working Mode | 5V PWM Dimming Signal |
Sensor Parameters | Operating Frequency | 5.8 GHz ±75 MHz, ISM Band. |
Transmitting power | 1mW Max. | |
Detection Area | 100%/50% | |
Hold time | 5s/5min/10min/30min | |
Stand-by Period | 0s/3min/10min/+∞ | |
Daylight Sensor | 30Lux/50Lux/100lux/Disable Daylight priority: ON / OFF value (30Lux)50Lux / 150Lux 100Lux / 200Lux (ambient light diffuse reflection conditions) |
|
Stand-by DIM Level | 10%/30% | |
Detecting Radius | mounting height 3m, 1m/S ≥2.5m | |
Mounting Height | 3m (6m Max ) | |
Detecting Angle | 90°@Xz plane / 130°@Yz plane | |
Operating Environment | Operating Temperature | -25℃…+70℃ |
Storage Temperature | -40℃…+80℃ Humidity: 85% (non-condensing) | |
Certificate | Environmental Requirement | RED |
Others | Wiring | 3 pin 2.0mm fast connector |
IP Rating | IP20 | |
Installation | Base installation | |
Dimension | See dimension | |
Package | card +cartons(K=A) | |
Net Weight | 18g | |
Lifetime | 5 years warranty@Ta | |
Note: 1. “N/A” means not available. 2. The detection range of the sensor is related to the moving speed and size of moving object, mounting height, installation height and angle, installation site, reflectors around the sensor etc. The data in the document is typical value and tested by a 165cm person in an open indoor area. The detection range at wall mounting will be longer at ceiling mounting. Please reduce detection sensitivity at wall mounting or contact us to confirm the sensor data settings. |
Initialization
After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns low brightness. During the initialization, the sensor is not able to detect movement.
Factory Setting
Detection area: 100%, Hold Time: 5s, Stand-by Period: 0s, Stand-by dim level: 10%, Daylight Sensor: Disable
Application Notice
Note: Sensor antenna should be above LED tray at least 2mm.