HomeProducts

MLC20C-NPS

Sensor DIM LED Driver

Get a Quote

Features

  • Metal strip non-isolated power supply; flicker-free PWM dimming power supply; with 12V auxiliary power supply; matching different sensor and wireless smart module.
  • Great performance, high efficiency, high PF value and low stand-by power; conforming to new ERP standard and complying to CE, SAA certification standards.
  • Built-in power supply is suitable for strip lamps; changing parameters by DIP switches.

Dimension & Function Diagram

Parameter characteristics

Input Voltage Range 198-264Vac 50Hz/60Hz
Input Current 0.1A (@230Vac full load)
Operating Voltage 220-240Vac 50Hz/60Hz
No-load Power ≤0.3W
Stand-by Power ≤0.3W
Power Factor ≥0.9 (@230Vac full load)
Working Efficiency 85% (230V Max load)
THD ≤20% (@230V ac full load)
Leak Current <0.5mA/240V
Surge Current <22A (100us half-current) @230Vac
Qutput Working model Constant Current
Type of load LED
Start Time ≤1S (@230Vac full load)
Ripple Current ±5% (@230Vac full load, LED full load)
Strobe Frequency
Requirement
Flicker free (≤5%)
No-load Output Voltage 65Vdc Max
Load Power 18.9W Max
Load Current 200mA/250mA/300mA/350mA(set by DIP switches)
Load Output Voltage Range 30-54Vdc
Connecting
Port
PWM Yes (5V and 3.3V PWM signals are compatible)
Port Connecting Method 3PIN PH2.0 row needles terminal
Auxiliary
Power supply
Voltage 12V±1V
Current Max100mA
Protection
Requirements
Operating Temperature/Humidity -25℃~+50℃
Storage Temperature/Humidity -40℃~+80℃  Humidity: 85% (Non-condensing)
Atmospheric Pressure 86~106KPa
Certificate
Standards
Safety Standards(LVD) EN61347-1,EN61347-2-13
EMC Standards EN55015,EN61547,EN61000-3-2,EN61000-3-3
Lightning surge LN: 1KV
Withstand Voltage 1500V AC 5mA 60s (input“L N” to output SEC+ SEC-)
Environmental requirement Compliant to RoHS
Certificate CE\ SAA
Others Output Current Accuracy ±5%
Wiring Press terminal, wire diameter: 0.5-1.0mm²
IP Rating IP20
Protection Class Class 2
Installation Built-in
Dimension 195*30*21mm
Net Weight 135g±3g
Warranty Five years warranty(Ta=50℃ @230Vac full load)

Product details

Application Notice

  1. Please use product according to specifications. Failure may occur if the product is used beyond the service conditions.
  2. Connect loads firstly before turning on the input power; otherwise, load may be damaged.
  3. After the LED drive input power is off, the output end still has residual voltage, which can be maintained for about 3 minutes.
  4. This product is a non-isolated power supply: a. To avoid electric shock, do not operate with power on before connecting load;  b. To avoid damaging sensing head, power off is also required before connecting.

Wiring suggestions

Installation suggestion