  • Isolated two-stage circuit frame, full dimming and flicker-free.
  • Support DIP switches to set the current gear.
  • Support 12V auxiliary power supply, with sensing split head can achieve integrated sensing function.
  • Equip with PWM dimming control port.
  • Suitable for various microwave sensors or wireless smart modules.

Dimension & Function Diagram

Parameter characteristics

Input Rated voltage 220-240V AC    50Hz/60Hz
Stand-by power ≤0.5W (Equip with Merrytek 5.8GHz sensing split head)
Surge 1KV(L/N, EN61000-4-5)
Power factor ≥0.95  (230V Max load)
Input current ≤0.23A @230VAC full load
Inrush current ≤20A(100us half-current)@230V AC
Working efficiency ≥86% (230V Max load)
Output Working model CC
Type of load LED
Flick ≤5%
Constant current accuracy Constant current accuracy ±5%
Auxiliary driver parameters 12VDC Current: 100mA Max
No-load output voltage 60VDC Max
Full load power 40W Max
Load current 600mA / 650mA / 700mA / 750mA
800mA / 850mA / 900mA / 950mA
1000mA / 1050mA
Load output voltage range 600mA / 9-42VDC
650mA / 9-42VDC
700mA / 9-42VDC
750mA / 9-42VDC
800mA / 9-42VDC
850mA / 9-42VDC
900mA / 9-42VDC
950mA / 9-42VDC
1000mA / 9-40VDC
1050mA / 9-38VDC
Abnormality Protection Requirements Protection mode Input overvoltage protection
Input no-load protection
Input short circuit protection
Environmental Requirements Operating temperature -25…+50℃
Maximum shell temperature(Tc) 85℃
Storage Temperature/humidity -40…+80℃  Humidity: ≤85%(non-condensation)
Certificate Standards Certificate CE、UKCA、SAA
Environmental requirement RoHS2.0, Reach requirement
Safety standards(LVD) EN61347-1, EN61347-2-13
EMC standards EN55015, EN61547, EN61000-3-2, EN61000-3-3
Withstand voltage Primary to secondary: 3.75KVAC
Primary to ground: 1.5KVAC
IP Rating IP20
Product Category Class I
Others Wiring method Press terminal, wire diameter: 0.5-1.0mm²
Installation Built-in
Package PE bag clapboard, carton(K=A)
Net weight 174±5g
Lifetime 5 years warranty@Ta 230V full load

Product details

Initialization

When powered on, it is steady on. When the sensor is configured, it changes according to the status of the sensor.

 

Default Setting

Adjust the corresponding current gear according to the order or customer demand.

 

Application Notice

  • Please use this product in accordance with the specifications. Failure may occur if the product is used beyond the use conditions.
  • The product should be installed by a professional electrician. Please turn off the power before installing, wiring, changing the setting of the DIP switches.
  • The load LED string must be connected first, and then turn on the input power, otherwise it may damage the LED string.
  • After the LED drive input is powered off, there will be residual voltage at the output end, which can be maintained for about 3 minutes.

Wiring suggestions