Input | Operating Voltage Range | 198-264V AC, 50Hz/60Hz |
Input Current | ≤0.23A | |
Rated Voltage | 220-240V AC, 50Hz/60Hz | |
Load Power | ≥0.90 (230V full load) | |
Stand-by Power | ≤1W | |
Working efficiency | 85% (230V Max load) | |
Wiring method | Press terminal, wire diameter:0.75-1.5mm² | |
Output | Working Model | Constant current |
Type of Load | LED | |
No-load output voltage | 55V DC Max | |
Full load power | 40W Max | |
Load output voltage range | 30-42V DC | |
Load output current | 950mA | |
Wiring method | Press terminal, wire diameter:0.75-1.5mm² | |
Sensor Parameters | Operating Frequency | 5.8 GHz ±75 MHz,ISM Band. |
Transmitting power | 1mW Max. | |
Hold time | 5S/90S/3min/10min | |
Stand-by DIM Level | 10%/25% | |
Stand-by Period | 0S/30S/10min/ +∞ | |
Detection Area | 25%/ 50%/ 75%/ 100% | |
Daylight Sensor | 5lux/15lux/30lux/Disable | |
Daylight on/off | N/A | |
Detecting Radius | 4-6m (mounting height 3m) (see note2) | |
Mounting Height | 6m Max. | |
Detecting Angle | 150° (Wall mounted), 360° (Ceiling mounted) | |
Wireless Module | Operating Frequency | N/A |
Transmitting power | N/A | |
Transmitting distance | N/A | |
Modulation mode | N/A | |
Number of coding | N/A | |
Operating Environment | Operating Temperature | -25℃…+50℃ |
Storage Temperature/Humidity | -40℃…+80℃(Humidity: 85% Non-condensing) | |
Certificate Standards | Safety standards | EN61347-1, EN61347-2-13 |
EMC standards | EN55015, EN61547, EN61000-3-2, EN61000-3-3 | |
Environmental Requirement | Compliant to RoHS | |
Certificate | TUV, CE | |
IP Rating | IP20 | |
Protection Class | Class II | |
Installation | Built-in installation | |
Dimension | Main Part: 212*42*30mm Sensor Head: 55*20*13.5mm |
|
Net Weight | 162.6g | |
Package | Bubble bag+Clapboard + Carton(K=A) | |
Lifetime | 30,000h @Ta 230V full load | |
Note: 1. “N/A”means not available. 2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s. |
Initialization
Factory Setting
Detection area: 100%, Hold Time: 5S, Daylight Sensor: Disable,Stand-by DIM level:10%,Stand-by period:30s
Application Notice
Be sure to power off before adjusting DIP switch setting.
*The sensor is designed for connect one load only. Connect more than one loads may damage the sensor.
N/A