Input | Operating Voltage Rage | 120-277V AC 50Hz/60Hz |
Rated Voltage | 220-240V AC, 50Hz/60Hz | |
Stand-by Power | ≤0.5W | |
Surge Test | L–N: 1kV | |
Output | Working Mode | ON/OFF function |
Type of Load | Inductive or Resistive | |
Load Capacity | 400W (Inductive) ; 800W (Resistive) | |
Max. Surge Capacity | 30A (50% Ipeak, twidth =500uS, 230Vac full load, cold start); | |
Sensor Parameters | Operating Frequency | 5.8 GHz ±75 MHz,ISM Band. |
Transmitting power | 1mW Max. | |
Hold time | 5S/30S/90S/5Min 10S/90S/3Min/10min (by remote MH03) |
|
Detection Sensitivity | 100%/75%/50%/25% 100%/50% (by remote MH03) |
|
Daylight Sensor | 25lux/Disable 5lux/15lux/50lux/Disable (by remote MH03) |
|
Detecting Radius | Ceiling mounting 3m high: 1m/S ≥2.5m (for built in lamp installation) Wall mounting 2m high: 1M /S ≥4m (for built in lamp installation) |
|
Mounting Height | 3m (Max 6m) | |
Detecting Angle | 150° (Wall mounted) | |
Operating Environment | Operating Temperature | -20℃…+60℃ |
Storage Temperature | -40℃…+80℃ (Humidity: ≤85% Non-condensing) | |
Certificate Standards | Safety standards | EN61058-1-2,EN61058-1 |
EMC standards | EN61000-3-2,EN61000-3-3,EN62479 EN301489-1,EN55015,EN300440 |
|
Environmental Requirement | Compliant to RoHS | |
Certificate | CE, RED | |
Others | Wiring | Press-in Type Terminals, wire diameter:0.75-1.5mm2 |
IP Rating | IP20 | |
Protection Class | Class II | |
Installation | Built-in | |
Dimension | 77.0*36.0*25.6mm | |
Package | Bubble bag+Clapboard + Carton(K=A) | |
Net Weight | 45±3g | |
Lifetime | 5 years warranty @Ta 230V full load |
Initialization
After power on, the sensor automatically turns on light at 100% brightness. After 10sec, it turns off the light. During the initialization, the sensor is not able to detect movement.
Factory Setting
Detection area: 100%, Hold Time: 5S, Daylight Sensor: Disable
Application Notice